GCU-OCD20 is designed for search and visualisation the place of portable systems of secret observation (SOS - Secret Observation System), camouflaged in the interior items, clothing and household goods for personal use, working or disconnected compact cameras under different lighting conditions. Device allows to detect electro-optical surveillance systems through the window as well as tined glasse, organic glass, and semitransparent mirror.
Basic operation principle is "cat's eye" effect (light-reflecting effect) lying in ability of optical objects to reflect probing radiation in opposite direction with angle close to its incidence angle. Semi-conducting laser IR diode (transmitting channel) serves as the source of probing radiation. The reflected signal is registered by sensitive video camera on the basis of interleave transfer sensor 1/3// (reception channel). The Device is developed on non-parallax optical scheme, i.e. with optical alignment of reception and transmitting channels.
 
Transmitting channel generates laser beam in the form of vertically located rectangular raster. Ability of illuminating raster can be changed if necessary, depending on distance to surveillance object, for reception of the best image contrast. Image focusing on sharpness is carried out by adjustment of video camera objective.

Visualization of surveillance objects is carried out through built in pseudo-binocular. In order to receive better images the body of the Device is equipped with fastening and connection for external 5"LCD-monitor (delivered on request of the Customer), and also with external CCIR standard video signal socket for connection with external monitor, video recorder or computer (with video input card).

Delivery set includes:

  1. GCU-OCD20 device;
  2. Video cable;
  3. LCD-monitor (with attachment point); (*optional)
  4. Charging unit;
  5. AC/DC converter;
  6. Rechargeable battery;
  7. Protective packing. Plastic case with foam-rubber pad.
Technical Characteristics:
Characteristics of radiation receiver
Type of receiver 1/2", CCD
Size of receiver 752x582 pixel
Lens of detector
Focal distance 25 mm
Angle of the field of vision 8° x 6°
Focusing range 1 m ... ∞
Action range
Distance of pupil detection, diameter 1 mm up to 25 m
Ocular and built-in display
Turning range of ocular ±4 dioptres
Display:
- type and display resolution
AMLCD 0,44",
640x480 pixel
Illumination
Type of built-in light source laser
Wavelength 808 nm
Angle of highlight area 2°x6°
Functional capabilities
- constant/pulse modes of laser illumination;
- brightness control.
Interface
Video PAL, LEMO connector
Self-contained power supply:
- Type of power supply
- Voltage of power supply

Storage battery
7V
Power supply:
- mains adapter
12 V
Operating continuous time under the normal climatic conditions. no less than 3 hours
Physical characteristics
Weight, with power sources 1,6 kg
Overall sizes 231x164x77 mm
Degree of protection IP65
Operating conditions
Operating temperature range -10°C...+40°C